Industrial battery chargers and rectifiers
Thyristor-controlled battery chargers
Rugged thyristor-based battery chargers and rectifiers for DC power supply applications in utilities and industry.

Overview
What it does
Statcon Energiaa thyristor-controlled industrial battery chargers convert AC to DC to charge battery banks while supplying continuous DC loads.
They are available in natural-cooled and forced-cooled designs, with float, float-cum-boost, dual and redundant configurations.
Transformers are manufactured in-house and systems can be customised for special applications.
Applications
- Power generation
- Transmission and distribution
- Defence
- Telecom
- Oil and gas
- Railways
- Other industrial DC power supply applications
Certifications and standards
- Input harmonic filters on request, designed to IEEE 519-2022 current-distortion limits
Features
Why engineers choose it
- Float-cum-boost charger with dropper diodes
- Dual float-cum-boost, and float plus float-cum-boost (FC + FCBC) systems
- Multiple chargers with a redundant standby charger
- Control circuit on glass epoxy board with digital and analog circuit blocks
- High transient response under specified load and line variations
- Class-F rectifier transformer, made in-house
- Protections: AC under/over voltage, DC under/over voltage, overload, thyristor fuse, blocking diode, soft start, surge suppressor, short circuit
- Customisation for special application requirements
Specifications
Key specifications
Configured to order. Full details are in the datasheet.
| Input supply | 230 V AC or 415 V AC, 50 Hz |
|---|---|
| Output voltage range | 24 V to 480 V DC |
| Current range | 10 A to 4,000 A |
| Charging method | Constant voltage float charging / constant voltage boost charging |
| Output voltage regulation | ±1% of rated voltage |
| Ripple | 3% RMS |
| Efficiency at rated output | Up to 85%, depending on rating |
| Input power factor | >0.85 under rated conditions; up to 0.99 possible on request |
| Input current harmonics | As per IEEE 519-2022, on request |
| Cooling | Natural air cooled or forced cooling |
| Enclosure protection | IP20 / IP31 / IP42 |
| Communication | Potential-free contacts or RS 485 interface for remote monitoring |
Typical values. Ratings and options may vary by model; confirm with the latest datasheet.