Statcon Energiaa

Load banks and dischargers

Resistive load banks and dischargers

Controllable resistive load banks and closed-loop battery dischargers for testing power sources and discharging batteries.

Dischargers: 24–220 V, up to 2,000 A; MW load bank range: 10 kW to 4,700 kW

Resistive load banks and dischargers

Overview

What it does

Statcon Energiaa load banks apply a contained, controllable electrical load to a power source to test, support or protect it, mimicking the real operating load.

Resistive dischargers hold a constant discharge current through closed-loop feedback with no operator needed, supporting 24–220 V up to 2,000 A.

For larger testing, a modular, scalable MW-class AC/DC load bank system has been built with PLC and HMI control.

Applications

  • Discharging batteries before the next charging cycle
  • Load testing of alternators, generators and diesel generator sets
  • Testing AC and DC sources at 50 Hz and 60 Hz
  • Testing ships and submarines under AC and DC load at a naval dockyard
  • Repair workshops and commercial and industrial buildings
  • Load testing of electrolyser rectifiers

Features

Why engineers choose it

  • Self-contained unit with load elements, control and accessory devices
  • Constant discharge current via closed-loop feedback
  • Resistive and inductive load testing of alternators and generators
  • Modular, scalable twin-unit design: run as one 3,000 kW system (master/follower) or two independent units
  • Comprehensive protection and alarm features
  • Factory tested before dispatch, including a rain test

Specifications

Key specifications

Configured to order. Full details are in the datasheet.

Discharger rating24 V to 220 V, up to 2,000 A
Discharger controlClosed-loop feedback for constant discharge current; no operator needed
Load typesResistive and inductive
MW load bank range10 kW to 4,700 kW (twin-unit system: 3,000 kW)
DC input (MW load bank)220 V to 360 V DC
AC input (MW load bank)380 V to 460 V AC and 690 V AC, 50/60 Hz
Control (MW load bank)PLC and HMI in each unit; local and remote user interface
Construction (MW load bank)Trolley-mounted, fixed type, or high-IP outdoor container
Environment (MW load bank)Operates in humidity, rain and dust; up to 50 °C without performance decline

Typical values. Ratings and options may vary by model; confirm with the latest datasheet.

Get in touch

Request a quote.

Need this configured for your site? Share the voltage, current and site conditions. An application engineer will reply with a configuration.

Call usRequest a quote