Thyristor rectifiers for electrolysers

Overview

What it does

High-power thyristor (SCR) rectifiers that supply stable, well-regulated DC to PEM and alkaline electrolysers, in 6, 12 and 24 pulse designs with galvanically isolated transformers, interphase transformers and filters.

Standard units deliver up to 10,000 A and 750 V DC from a 415 V or medium-voltage supply, with forced air cooling that avoids air conditioning and full output up to 50 °C outdoors.

Modular units can be paralleled for redundancy and expansion, and a PLC with touchscreen HMI provides remote operation and data logging.

Applications

  • PEM electrolyser plants
  • Alkaline electrolyser plants
  • Green hydrogen mobility and pilot projects
  • Utility-scale green hydrogen production
How a rectifier feeds an electrolyser: renewables and grid, rectifier, electrolyser, storage

Features

Why engineers choose it

  • Single-stage conversion for high efficiency
  • Galvanically isolated transformer with custom interphase transformers and filters
  • Forced air cooling with no need for air conditioning
  • Full rated output up to 50 °C outdoors
  • Modular units that can be paralleled for redundancy and expansion
  • Wide input supply range for harsh tropical conditions
  • Protection against over current, short circuit, over voltage and over temperature
  • 25-year service life with locally available spares and service

Specifications

Key specifications

Configured to order. Full details are in the datasheet.

Input supply415 V, 50/60 Hz; 6.6 kV / 11 kV / 33 kV on request
Output voltageUp to 750 V DC (up to 1000 V on request); modular range 350–750 V DC
Output currentUp to 10,000 A DC (up to 25,000 A on request)
TopologyThyristor (SCR), single-stage conversion; 6, 12 or 24 pulse
RegulationStepless constant voltage or constant current, 10–100%; ±1% precision
Input current THD12% / 5%
Output ripple≤ 2%
DutyContinuous at rated load
CoolingForced air-cooled; water-cooled on request; air- or oil-cooled isolation transformers
EnclosureIndoor panel, outdoor container or trolley-mounted
Max ambient without derating45 °C indoor, 50 °C outdoor
Control/HMIPLC with touchscreen HMI; remote operation and data logging

Typical values. Ratings and options may vary by model; confirm with the latest datasheet.